Bathrooms Learning Center · 15 min read · Updated November 2026

Shower Pan Liner or Bonded Sheet Membrane (Kerdi-Type): What Is the Difference, and Does Florida Allow Both?

Short answer

A pan liner is a loose sheet of PVC or CPE laid under the mortar bed, so water that gets through the tile soaks down to it and leaves through the weep holes of a clamping-ring drain; a bonded sheet membrane (Schluter KERDI is one brand) is glued with thin-set on top of the mortar bed, so tile goes straight on it and water stays at the top, running into a drain with a bonding flange [3][5][6]. Florida allows both: the Florida Building Code, Plumbing, §421.5.2 lists PVC sheet (ASTM D4551), CPE sheet (ASTM D4068), sheet lead, sheet copper and “sheet-applied, load-bearing, bonded, waterproof membranes” meeting ANSI A118.10 as shower linings, and the Residential volume’s §P2709.2 has the same list [1][2]. You use one or the other, not both, and the drain has to be the kind made for the layer you chose [3][6].

Second shower: PVC pan liner set in new framing with drain opening in Sarasota, Florida by PRO PLUMBERS FL, LLC (licence CFC1432506)
Second shower: PVC pan liner set in new framing with drain opening in Sarasota, Florida

What is the difference between a shower pan liner and a bonded sheet membrane?

The difference is where the waterproof layer sits and where the water goes. A pan liner sits under the mortar bed; a bonded sheet membrane sits on top of it, directly under the tile [3][5].

In the traditional build, a first layer of mortar (the pre-slope) is sloped to the drain, the pan liner is laid over it and clamped into the drain, and a second mortar bed goes on the liner for the tile. Schluter’s own handbook describes it that way: “a mortar bed is sloped to the weep holes in the drain,” the pan liner “is placed over this ‘pre-slope’ and clamped into the drain,” and water that gets through the tile “must percolate through the mortar bed to the sloped pan liner and exit through the weep holes in the drain” [3]. Oatey, which makes the liner in our photograph, gives the same sequence: mortar sloped a quarter inch per foot, the liner, the drain’s clamping ring tightened against it, then “a mortar base on top of the pan liner” [4]. The layers of that pan are drawn out in our article on what is under your shower floor.

In the bonded build there is one sloped mortar bed, and the membrane is bonded to the top of it with thin-set. Schluter’s handbook puts it in one sentence: “Unlike shower pan liners in traditional assemblies, KERDI is a bonded waterproofing membrane that allows for the direct application of tile with thin-set mortar.” The membrane is bonded to the bed and to the drain’s integrated bonding flange, and the handbook says the result “does not permit moisture to penetrate into the mortar bed” [3]. KERDI is 8 mil thick; seams overlap 2 inches or are abutted and covered with its seaming band [3].

So the two layers do different jobs. The liner is a safety floor under a mortar bed that is expected to get wet; the bonded membrane is a skin that keeps the bed dry in the first place. Schluter calls the first a “water in / water out system” and the second a “sealed system” [3]; Oatey’s blog says that a traditional liner install needs the subfloor “counter-pitched to a subdrain,” while “topical waterproofing (liquid or fabric) minimizes the water buildup that can degenerate the pre-slope below” [5].

Pan liner or bonded membrane floor cut at the drain · not to scale A Pan liner B Bonded sheet 1 2 3 4 5 6 7 8 9 10 1 Pre-slope: mortar sloped to the drain, laid under the liner. 2 PVC or CPE pan liner, loose-laid and turned up the wall. 3 Second mortar bed on the liner; the tile is set on this bed. 4 Clamping-ring drain: the liner is clamped at its flange; weep holes at liner level. 5 Water that gets past the tile soaks down to the liner and leaves by the weep holes. 6 One mortar bed, sloped to the drain. No liner under it. 7 Sheet membrane bonded to the top of the bed with thin-set, turned up the wall. 8 Thin-set and tile straight on the membrane. 9 Bonding-flange drain: its flange sits at the top of the bed; the membrane bonds to it. 10 Water stays on top of the membrane and runs across the tile into the drain. Our own drawing. Thicknesses exaggerated; wall board and curb left out for clarity.
Our own drawing, not to scale. Section A follows the traditional sequence in Oatey’s and Schluter’s instructions: pre-slope, loose liner, mortar bed, tile, clamping-ring drain with weep holes [3][4][5]. Section B follows Schluter’s handbook: one sloped bed, membrane bonded on top, tile on the membrane, drain with a bonding flange at the top of the bed [3]. — drawing by Pro Plumbers FL

Does Florida allow both a PVC pan liner and a Kerdi-type membrane?

Yes. Both are on the list of shower lining materials in the Florida Building Code, 8th edition (2023), in both the Plumbing and the Residential volumes [1][2].

The Plumbing volume, §421.5.2, says floors under shower compartments, except prefabricated receptors, “shall be lined and made water tight utilizing material complying with Sections 421.5.2.1 through 421.5.2.6.” Those six subsections are: PVC sheets meeting ASTM D4551, joined by solvent welding (§421.5.2.1); chlorinated polyethylene (CPE) sheets meeting ASTM D4068 (§421.5.2.2); sheet lead (§421.5.2.3); sheet copper to ASTM B152 (§421.5.2.4); “sheet-applied, load-bearing, bonded, waterproof membranes” meeting ANSI A118.10 (§421.5.2.5); and liquid-type, trowel-applied, load-bearing, bonded waterproof materials meeting ANSI A118.10 (§421.5.2.6) [1].

The Residential volume, §P2709.2, has the same families for an on-site built-up shower receptor: sheet lead, sheet copper, plastic liner material to ASTM D4068 or D4551, hot mopping, and “sheet-applied load-bearing, bonded waterproof membranes that comply with ANSI A118.10” [2].

ANSI A118.10 is what separates a bonded membrane from an ordinary sheet of plastic. TCNA, which publishes the tile installation standards, lists it as the “American National Standard Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile and Dimension Stone Installation,” 2023 edition [7]. Schluter reports KERDI’s results against it, among them no moisture penetration in the waterproofness test, and its system carries an ICC-ES product listing, PMG-1204, that names ANSI A118.10-2023 and was evaluated under the 2006 through 2024 International Plumbing and Residential Codes [3][8].

Two code details are specific to bonded membranes. Both volumes say a bonded sheet membrane used as the shower lining “shall not be required to be recessed,” since a thin membrane on the face of the wall does not take up the space a thick liner does, and both say it shall be applied “in accordance with the manufacturer’s installation instructions,” which is why the maker’s handbook, not the code, sets the overlap, the thin-set and the drain [1][2]. The ICC-ES listing adds that those instructions must be available at the jobsite during installation [8].

The rules that apply to every lining type are the same for both: turned up at least 2 inches above the finished threshold, not nailed or perforated less than 1 inch above it, sloped a quarter inch per foot to the drain, and water-tested [1][2].

Do I need a pan liner if I use Kerdi?

No. The code asks for one lining that complies with one of the listed materials, and a bonded sheet membrane to ANSI A118.10 is one of them, so the membrane is the liner [1][2].

Schluter’s handbook has no pan liner anywhere in its own system. Its floor is a mortar bed sloped a quarter inch per foot, using the drain’s bonding flange and a perimeter screed as guides, at least 1 inch thick at the flange over wood or three-quarters of an inch over concrete; “as soon as the mortar bed can be walked upon,” the membrane goes on, and the tile is set straight on the membrane with thin-set [3].

What you do still need is the slope. The code requires the lining to be pitched a quarter inch per foot toward the drain, made, in the Residential volume’s words, “by means of a smooth, solidly formed subbase” [1][2]. In the traditional build that is the pre-slope under the liner; in the bonded build it is the one mortar bed the membrane is glued to, and the ICC-ES listing for Schluter’s system makes “shower floors must be sloped toward the drain” a condition of the listing [3][8]. Both makers warn about skipping it: Schluter says a liner laid without a pre-slope is the case where “the mortar bed can remain saturated,” and Oatey says “many installers make the mistake of not pre-sloping before installing the waterproofing layer” [3][5].

Nor do you stack the two. The code asks for material complying with one of its subsections, and nothing in either maker’s instructions puts a bonded membrane over a pan liner or a liner under one; in trade practice a shower gets one system or the other, and the drain is chosen to match [1][2][3][4].

Does the drain have to match the waterproofing?

Yes. Each layer is sealed to the drain at a different height, so each needs a drain built for that height [3][6].

A pan liner is sealed at the bottom of the assembly. The code says the liner shall be “securely fastened to the waste outlet at the seepage entrance, making a water-tight joint between the liner and the outlet,” and the Residential volume describes that drain: a flanged drain flush with the subbase, “equipped with a clamping ring or other device to make a water-tight connection between the lining and the drain,” whose “flange shall have weep holes into the drain” [1][2]. Oatey’s 130 series tile shower drain is that kind, “designed for use with tile or marble showers where a shower pan liner is used,” with a clamping collar that bolts down on the liner and weep holes that “allow drainage from the pan liner” [6]. Oatey’s blog adds the practical rule: keep the weep holes clear of liner scraps and silicone when the ring goes on, and protect them with weep guards or pea gravel so the mortar bed does not clog them [5].

A bonded membrane is sealed at the top of the assembly. Schluter’s drain has what it calls an integrated bonding flange that “ensures waterproof connection at top of assembly”: thin-set is spread on the flange, a membrane collar is embedded in it, and the floor membrane overlaps the collar [3]. The handbook is explicit about what to do with the other kind of drain: “If a clamping ring drain is installed, replace with KERDI-DRAIN or convert using the KERDI-DRAIN-A adaptor kit” [3].

Our reading of those sources: a clamping-ring drain has nothing at tile level to bond a membrane to, and a bonding-flange drain has no clamping ring or weep holes at liner level, so a drain of one type with a lining of the other leaves the waterproof layer unsealed at the drain. The shapes of drain you can choose within each family are in our article on square, round or linear shower drains.

Which one is in my shower?

If the floor is tiled, the drain is usually the only visible clue, and it is not always conclusive. A traditional clamping-ring drain has a round strainer on a threaded barrel that was screwed up to tile height [6]. A bonding-flange drain has a grate that sits in a frame at tile level; Schluter’s point drains and linear drains are both made that way [3]. Anything beyond that, such as pulling a grate or opening a wall, is a job for whoever is doing the repair.

During construction it is obvious. A pan liner is a loose, thick grey or black sheet you can lift at the edges, lying on mortar with the studs bare above it, and the drain is a two-piece body with a bolted ring, like the one in our photograph [4][6]. A bonded membrane is a thin, fabric-faced sheet (Schluter’s is orange) that is glued down and cannot be lifted, with the tile going straight onto it [3].

If the question comes up because the shower is leaking, the type of lining is found by testing, not by guessing; the symptoms and the usual fixes are in our article on signs of a leaking shower pan, linked below.

Is a bonded membrane better than a pan liner?

The code does not rank them: both are compliant linings when installed to their own rules [1][2]. What differs is what each one does with water, and that is documented by the makers rather than by an independent study we could read.

Schluter, which makes bonded membranes, says the traditional assembly lets water “saturate the mortar bed before exiting the system through the weep holes,” and that its bonded assembly keeps the bed dry; it also says ANSI A118.10 covers liquid water only and sets no minimum for vapour transmission [3][9]. Oatey, which makes both pan liners and topical waterproofing, says a traditional liner needs the subfloor pre-sloped and the weep holes kept clear, and that topical waterproofing “minimizes the water buildup that can degenerate the pre-slope below” [5].

Our reading: a pan liner done to the code and the maker’s instructions, with a pre-slope and open weep holes, is a code-recognised shower floor in Florida, and so is a bonded membrane with its matching drain. The failures each is known for are specific: a liner laid flat or with blocked weep holes holds water in the bed; a membrane with a seam that did not overlap or a collar that did not bond leaks at the top [3][5]. Which to use depends on the drain you are starting with, the floor you are building on and the tile setter’s system, and that is a conversation to have before the rough-in, not after.

Seams are their own subject, with their own rules for each material: see can a shower pan liner have a seam.

What this means in Sarasota, Clearwater and across Tampa Bay

Florida has one statewide building code, and the lining list on this page is from its 8th edition (2023), the Plumbing volume’s §421.5.2 and the Residential volume’s §P2709.2 [1][2]. Both volumes list PVC and CPE sheet and ANSI A118.10 bonded membranes, so either system can be permitted and inspected anywhere in Pinellas, Hillsborough, Manatee or Sarasota County; what the inspector checks is the turn-up, the slope, the fastening and the water test, which are the same for both [1][2].

The photograph is a pan liner we installed in a new-framed shower in Sarasota: a grey Oatey 40 mil PVC liner laid in a long alcove and turned up the wood stud walls, with the bare concrete floor visible, a black clamping-ring drain in the opening at the middle of the floor, and a braided supply line and red and blue PEX at the right. It is section A of our drawing, before the mortar bed and tile. If you are planning a tiled shower and have not yet decided between a liner and a bonded membrane, call 727-470-7126 and tell us which drain and which tile system you are starting with.

Building a Tiled Shower Floor?

Tell us the shower size, the drain you have or want and whether your tile setter is using a liner or a bonded membrane. Kate, our AI voice assistant, answers the phone 24/7 and takes the request; overnight requests are reviewed first thing in the morning, and site work is Monday to Friday, 8am to 6pm. We speak English and Russian.

Call 727-470-7126

FAQ

Do I need a pan liner if I use Kerdi?

No. A sheet-applied, load-bearing, bonded waterproof membrane meeting ANSI A118.10 is itself one of the shower linings listed in Florida’s code, and Schluter’s handbook builds its floor as one sloped mortar bed with the membrane bonded on top and the tile on the membrane, with no liner [1][2][3].

Is Kerdi allowed by code in Florida?

Yes. The Florida Building Code, Plumbing, §421.5.2.5 and the Residential volume §P2709.2 both list sheet-applied, load-bearing, bonded waterproof membranes meeting ANSI A118.10 as a shower lining, applied per the manufacturer’s instructions [1][2]. Schluter reports KERDI tested to ANSI A118.10 and holds an ICC-ES listing, PMG-1204, that names that standard [3][8].

PVC or CPE: which pan liner is code in Florida?

Both. §421.5.2.1 covers plasticized PVC sheet meeting ASTM D4551, joined by solvent welding, and §421.5.2.2 covers CPE sheet meeting ASTM D4068; the Residential volume accepts plastic liner material complying with either standard [1][2].

Can I use a Kerdi drain with a PVC pan liner, or a clamping-ring drain with Kerdi?

Not according to the makers. Oatey’s clamping-collar drain is for showers where a pan liner is used, and its weep holes drain the liner; Schluter’s drain bonds the membrane to a flange at the top of the assembly, and its handbook says to replace or convert a clamping-ring drain when installing its system [3][6]. The code requires a water-tight joint between the lining and the outlet, and each drain makes that joint only with its own layer [1][2].

Does a Kerdi shower need a pre-slope?

It needs a slope, but only one bed. The code requires the lining to be pitched a quarter inch per foot to the drain, and Schluter’s handbook slopes its single mortar bed at that rate and bonds the membrane to it; the traditional pre-slope-plus-liner-plus-bed sequence is not used [1][2][3].

What are weep holes, and does a bonded-membrane drain have them?

Weep holes are the small openings at the liner level of a clamping-ring drain that let water on the liner into the drain; the Residential code requires them in a drain used with a lining, and Oatey says to keep them clear with weep guards or pea gravel [2][5][6]. A bonded membrane is sealed at the top of the drain instead, so the water never reaches the liner level [3].

Does a bonded membrane shower still get a flood test?

Yes. Florida’s §312.9 applies to any lining made with the materials in §421.5.2: the drain is plugged, the floor filled to at least 2 inches at the threshold and held for at least 15 minutes with no leakage [1]. Schluter strongly recommends a water test before tiling and waiting at least 24 hours after the membrane goes on; Oatey recommends at least four hours for a liner [3][5].

How can I tell if my finished shower has a liner or a membrane?

From the drain, mostly: a round strainer on a threaded, height-adjusted barrel points to a clamping-ring drain and a pan liner, while a grate set in a frame at tile level, round or linear, points to a bonding-flange drain and a bonded membrane [3][6]. It is a clue, not proof; a leak is diagnosed by testing.

Sources

We review and cite. We do not reproduce a paper or a manual — follow the links for the originals.

  1. [1]Florida Building Code, Plumbing, 8th Edition (2023) — §421.5 Shower floors or receptors, §421.5.2 Shower lining and §421.5.2.1–421.5.2.6; §312.9 Shower liner test — Florida Building Commission / International Code Council · 2023Law / code · §421.5.2: floors under shower compartments, except prefabricated receptors, “shall be lined and made water tight utilizing material complying with Sections 421.5.2.1 through 421.5.2.6”; liners turn up on all sides not less than 2 in above the finished threshold; recessed and fastened to an approved backing; not nailed or perforated less than 1 in above the finished threshold; pitched 1/4 in 12 toward the fixture drains and “securely fastened to the waste outlet at the seepage entrance, making a water-tight joint between the liner and the outlet”; completed liner tested per §312.9. Exception 2: a sheet-applied, load-bearing, bonded, waterproof membrane used as the lining “shall not be required to be recessed”. §421.5.2.1 PVC sheets ASTM D4551, joined by solvent welding per the manufacturer; §421.5.2.2 nonplasticized CPE sheet ASTM D4068; §421.5.2.3 sheet lead 4 lb/sq ft; §421.5.2.4 sheet copper ASTM B152, 12 oz/sq ft; §421.5.2.5 “Sheet-applied, load-bearing, bonded, waterproof membranes shall meet requirements of ANSI A118.10 and shall be applied in accordance with the manufacturer’s installation instructions”; §421.5.2.6 liquid-type, trowel-applied, load-bearing, bonded waterproof materials, ANSI A118.10. §312.9 (chapter 3, same viewer): where floors are made water tight with §421.5.2 materials the completed liner is tested, drain plugged, filled with potable water to not less than 2 in at the threshold, held not less than 15 minutes with no evidence of leakage. Page header: “2023 FBC - Plumbing, 8th edition”, adopts IPC 2021 with amendments; read in a browser on UpCodes; read 2026-11-23
  2. [2]Florida Building Code, Residential, 8th Edition (2023) — §P2709 Shower receptors: §P2709.2 Lining required, §P2709.2.1–P2709.2.4, §P2709.3 Installation, §P2709.4 Receptor drains — Florida Building Commission / International Code Council · 2023Law / code · §P2709.2: walls and floor framing enclosing on-site built-up shower receptors “shall be lined with one of the following materials”: sheet lead; sheet copper; plastic liner material complying with ASTM D4068 or ASTM D4551; hot mopping per §P2709.2.3; “sheet-applied load-bearing, bonded waterproof membranes that comply with ANSI A118.10”; lining extends not less than 2 in beyond the rough jambs and 2 in above finished thresholds; bonded membranes applied per the manufacturer’s instructions; exception 2: a bonded sheet membrane used as the lining need not be recessed. §P2709.2.1 PVC ASTM D4551; §P2709.2.2 CPE ASTM D4068; §P2709.2.4 liquid-type trowel-applied materials, ANSI A118.10. §P2709.3: lining sloped 1/4 in 12 “to weep holes in the subdrain by means of a smooth, solidly formed subbase”, recessed and fastened to approved backing, not nailed or perforated less than 1 in above the finished threshold. §P2709.4: “An approved flanged drain shall be installed with shower subpans or linings. The flange shall be placed flush with the subbase and be equipped with a clamping ring or other device to make a water-tight connection between the lining and the drain. The flange shall have weep holes into the drain.” §P2709.4.1 flanged drains to ASME A112.18.2/CSA B125.2. Page header: “2023 FBC - Residential, 8th edition”, adopts IRC 2021 with amendments; read in a browser on UpCodes; read 2026-11-23
  3. [3]Schluter-Shower System Installation Handbook — Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds (04/2026) — Schluter-Systems L.P. · 2026Manufacturer's manual · One maker’s instructions, not a brand shown in our photograph. Introduction on the traditional method: “a mortar bed is sloped to the weep holes in the drain”, the pan liner “is placed over this ‘pre-slope’ and clamped into the drain”, moisture “must percolate through the mortar bed to the sloped pan liner and exit through the weep holes”, and “the mortar bed can remain saturated, particularly if pre-slope installation is ignored”. “Unlike shower pan liners in traditional assemblies, KERDI is a bonded waterproofing membrane that allows for the direct application of tile with thin-set mortar”; bonded to the mortar bed or tray and to the KERDI-DRAIN’s integrated bonding flange “at the top of the assembly”; the assembly “does not permit moisture to penetrate into the mortar bed”. p.5 thickness 8 mil; “Integrated bonding flange ensures waterproof connection at top of assembly”; adaptor kits convert an existing clamping ring drain. p.6 seams and fastener penetrations treated with KERDI-BAND or KERDI with a 2 in overlap; p.29 seams overlapped 2 in or abutted. p.7 all horizontal surfaces sloped toward the drain; water test strongly recommended before tile; p.34 wait 24 hours minimum after the membrane. p.10 certified by ICC-ES, Report PMG-1204. p.26 mortar bed at least 1 in thick at the bonding flange over wood, 3/4 in over concrete; “Slope the mortar bed at 1/4 in (6 mm) per 12 in (305 mm) using the bonding flange and a perimeter screed as guides”; “If a clamping ring drain is installed, replace with KERDI-DRAIN or convert using the KERDI-DRAIN-A adaptor kit”. p.27 “As soon as the mortar bed can be walked upon” the membrane goes on. p.30 embed the KERDI collar in the bond coat on the bonding flange. p.31 refer to local plumbing and building codes. p.50 test data to ANSI A118.10 “Load Bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile”: waterproofness pass (no moisture penetration), 7-day shear 84 psi vs 50 psi required, fungus resistance pass; UPC listed. p.51–52: traditional method “creates a water in / water out system”, moisture “is allowed to saturate the mortar bed before exiting the system through the weep holes”; the Schluter system “creates a sealed system”; ANSI A118.10-S judges products as “barriers to liquid water only” and “does not include a minimum criterion to establish the ability of products to limit vapor transmission”. Read 2026-11-23
  4. [4]How to Install a Shower Pan Liner (project guide) — Oatey Co.Manufacturer's manual · Undated web page. One maker’s instructions; Oatey is the maker named for the liner in our photograph. Step 2 prepare slope: “Pour mortar onto the subfloor at 1/4 inch per foot sloped inward” (or Oatey’s pre-formed slope). Step 4: mark 5 in up from the curb on the wall framing to set the liner height. Step 5: “Cut X shapes over the four bolts that the clamping ring screws into”. Step 6: fold the liner back, apply silicone around the inner flange, “tighten the bolts until the ring has a snug fit against the liner”. Step 10 flood test: fill to a height equal to the curb; “There are no leaks if the water level hasn’t dropped”. After step 10 the next stage is “applying a mortar base on top of the pan liner”. The guide does not mention weep holes. The printed instruction PDF (LCS993) on oatey.com is an image file we could not read. Read 2026-11-23
  5. [5]Shower Installation and Waterproofing: Tips & Common Errors (blog, 26 July 2021) — Oatey Co. · 2021Manufacturer's manual · One maker’s guidance. For traditional liner installs (PVC, CPE or hot mop) “the subfloor below the liner must be counter-pitched to a subdrain”; the sloped bed sits flush with the top edge of the two-piece clamp collar base; “Many installers make the mistake of not pre-sloping before installing the waterproofing layer”. “These weep holes are integrated into both clamp collar drains and most shower systems”; “Installers can utilize weep guards or pea gravel around the drain barrel to ensure the weep holes do not get clogged”; “When installing the drain clamping ring, ensure the weep holes are clear of any residual pan liner or silicone”. Flood test with a test plug, filled to just below the flood level or slightly below the curb; “Oatey recommends a minimum testing time of four hours”; check the local code jurisdiction. “Topical waterproofing (liquid or fabric) minimizes the water buildup that can degenerate the pre-slope below.” Read 2026-11-23
  6. [6]Oatey 130 Series Tile Shower Base Drains (product page) — Oatey Co.Manufacturer's manual · Undated web page. One maker’s clamping-ring (clamping-collar) drain. “Designed for use with tile or marble showers where a shower pan liner is used”; “Reversible clamping collar secures with stainless steel bolts”; “Weep holes allow drainage from the pan liner”; threaded strainer barrel for height adjustment. The page does not state the drain’s standards. Read 2026-11-23
  7. [7]ANSI Standards (A108, A118, A136 tile installation standards listing) — Tile Council of North America (TCNA) · 2023Government or standards body · TCNA is the trade standards body that sells the ANSI tile installation standards and acts as secretary of the ASC A108 committee. Lists ANSI A118.10 as the “American National Standard Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile and Dimension Stone Installation”, 2023 edition, current. The page gives the title only, not the test requirements. Read 2026-11-23
  8. [8]ICC-ES PMG Product Certificate PMG-1204 — Schluter Shower System — ICC Evaluation Service, LLC · 2026Government or standards body · Listing for the Schluter Shower System (KERDI, KERDI-DS, DITRA family membranes, KERDI-BAND, KERDI-DRAIN, KERDI-LINE, KERDI-SHOWER trays), effective August 2026. Evaluated under the 2024, 2021, 2018, 2015, 2012, 2009 and 2006 International Plumbing Code and International Residential Code, plus the UPC and other codes; standards named: ASME A112.6.3/CSA B79.3-2022 floor drains, ASME A112.18.2/CSA B125.2-2020 plumbing waste fittings, IAPMO PS 106-2015e1, ANSI A118.10-2023. Conditions: installed per the manufacturer’s published instructions and the applicable codes; “The manufacturer’s published installation instruction must be available at the jobsite at all times during installation”; “Shower floors must be sloped toward the drain”. The listing does not cite code section numbers or a turn-up height. It is an ICC-ES listing, not a Florida approval. Read 2026-11-23
  9. [9]Comparing traditional showers to bonded waterproof assemblies (technical article) — Schluter-Systems L.P.Manufacturer's manual · Undated web page. Vendor-written comparison by Schluter staff promoting its own system. Traditional: mortar bed sloped to the weep holes, liner (lead, copper, PVC, CPE or hot mop) clamped into the drain; “Because pan liners are not designed to allow for the direct application of tile a mortar bed must be installed”; water enters the tile substrate, weep holes can clog and the bed can stay saturated. Bonded: sheet membrane bonded with thin-set to a sloped base, “applied topically (on the surface), with all water directed into the top of the drain” via a drain with an integrated bonding flange; adaptor kit converts an existing clamping drain. States ANSI A118.10 covers liquid water only and sets no vapour minimum. Cites TCNA Handbook methods B414/B415 (traditional) and B422 (bonded). Its mold and cost claims are unquantified and not used. Read 2026-11-23

Related Services

PEX-A Shower & Tub Rough-In Shower & Tub Trim

From the Learning Center

What Is Under Your Shower Floor — and Why It Matters Square, Round or Linear Shower Drain — What Is the Difference, and What Size Drain Does a Shower Need? How to Tell If Your Shower Pan Is Leaking — and What the Fix Involves

Questions About Your Own System?

Send a photo of what you have. We answer with what it is and what it needs.

See our PEX-A Shower & Tub Rough-In service →

Licensed CFC1432506 · Insured · Clearwater, FL + 50 miles

Call 727-470-7126